Go back to RESOURCES Vessel System Brochure Download
MultiCell Lite Handout
ISC Webmaster2019-11-12T12:09:10-05:00Go back to RESOURCES Multicell Lite Handout Download
MultiCell Handout
ISC Webmaster2019-11-12T10:49:16-05:00Go back to RESOURCES Multicell Handout Download
MyoStretcher Handout
ISC Webmaster2019-10-22T18:13:34-05:00Go back to RESOURCES WorkLoops Handout Download
Workloops Handout
ISC Webmaster2019-10-29T19:48:07-05:00Go back to RESOURCES WorkLoops Handout Download
C-Pace EM Brochure
ISC Webmaster2020-12-01T17:22:38-05:00Go back to RESOURCES C-Pace EM Brochure Download
Motic AE31 Manual
ISC Webmaster2019-10-21T17:02:53-05:00Go back to RESOURCES Motic AE31 Manual Download
Intact Muscle Chamber Handout
ISC Webmaster2019-10-22T18:51:08-05:00Go back to RESOURCES Intact Muscle Chamber Handout Download
Setting Up An Experiment In IW6
ISC Webmaster2019-10-19T01:24:06-05:00This document explains how to set up the software to run an experiment.
Hardware Configuration IW6 With IO24 And Mutech Cards
ISC Webmaster2019-10-22T18:28:39-05:00This document contains a step-by-step guide for the hardware configuration of IonWizard 6 under windows XP.
How To Upgrade To A New Version Of IW6
ISC Webmaster2019-10-19T01:12:52-05:00These documents explains how to upgrade from an existing version to a newer version of IonWizard 6.
Transient Analysis Features
ISC Webmaster2019-10-22T20:13:07-05:00The following document provides a full description of the mathematical fit of the data followed by a description of each of the analysis results and their application.
Mutech And IO24 Card Installation For IW6
ISC Webmaster2019-10-19T00:31:21-05:00This document contains a step by step guide for the installation of the new IO24 PCI card and Mutech video card used for contractility and diameter measurements.
SarcLen & FFTs
ISC Webmaster2019-10-19T00:25:21-05:00Applying a Fast Fourier Transform to Sarcomere Length Measurements
Plotting Calcium And Contractility
ISC Webmaster2019-10-19T00:15:44-05:00The following is a Excel spreadsheet with a macro enabling the interpolation of data exported from IonWizard.
Plotting Hysteresis Loops
ISC Webmaster2019-10-19T00:14:32-05:00The following document details a procedure for plotting both calcium and contracility
SarcLen Algorithm
ISC Webmaster2019-10-18T23:48:45-05:00The following document describes the application of the fast Fourier transform to sarcomere length using IonOptix SarcLen.
Testing MyoPacer Outputs
ISC Webmaster2019-10-21T19:17:48-05:00This tech note describes how to use a standard volt meter to evaluate that the high voltage output of your myopacer is functioning properly.
Replacing Your Xe Bulb
ISC Webmaster2019-10-21T19:44:21-05:00A brief guide to properly replacing your Xenon bulb with plenty of helpful pictures.